Calibration & testing
Choose acceptance checks for the signals and feedback channels that the project uses. Record the hardware, firmware, host software and test conditions with the results.

Project checks
Motion capture
Check hand fit and the starting pose. Repeat the same finger motions and review joint direction, dropped frames and any response delay in the connected system.
Tactile capture
Verify the channel positions and zero-load baseline. Apply and release a repeatable contact and check the recorded peak, baseline recovery and time alignment.
Haptic and force feedback
Check each fitted feedback channel against its command and confirm the release behavior. Define the measurement conditions and allowable operating range for the selected hardware.
What to record during a trial
- Setup: sample ID, software version, calibration pose and test conditions.
- Motion capture: repeat an open hand, fist and pinch. Save a short recording to check joint direction and missing frames.
- Tactile capture: record the signal before contact, during a hold and after release. Check that the signal returns toward its starting level.
What to agree for the order
Agree pass criteria before testing. Record the sample ID, test setup, result and any issue that needs a second check.