ZIXITECHROBOTICS · FLEXIBLE SENSING
English中文
Product knowledge2 min read

What does a tactile glove record?

A practical way to read contact signals before collecting robot-learning demonstrations.

Glove sample with fingers flexed · configuration to be confirmed

The essentials

  • Coverage varies: fingertips, palm or other sensed regions.
  • Raw sensor readings are not automatically calibrated force.
  • A representative recording helps clarify the configuration.
On this page

Contact, recorded on a glove

A tactile data collection glove records contact as a person handles objects. The useful starting point is where and when the hand meets the object.

  • Confirm which hand regions are sensed.
  • Ask what each channel measures.
  • Do not assume every glove has full-hand coverage.

Contact is different from pose

Hand pose describes movement or configuration. A tactile signal describes interaction at a sensed location. If the task needs both, define two data streams and how they will be recorded together.

Read the channel map first

Ask for a map connecting each recorded channel to its location on the glove.

  • Raw reading or calibrated physical value?
  • What are the units and calibration conditions?
  • Measured channel or software estimate?
Back-of-hand sample view · not a model specification

How a tactile array becomes a data stream

In this example, contact deforms a soft layer above a capacitive array. The digitizer reads changes in capacitance, and an external processor can use those readings to estimate force. A project brief should specify whether it needs raw sensor readings, calibrated measurements or a force estimate.

Make the first recording small

Use one representative object and a repeatable handling sequence.

  1. Pick up
  2. Hold
  3. Release
  • Mark the beginning and end of the recording.
  • Confirm timestamps and any video alignment.
  • Save the hardware and calibration versions.

A research example

MIT CSAIL’s STAG research illustrates recording contact patterns across the hand during grasping. It is a separate research system, not a specification or validation of ZixiTech ZX-Sensor-Glove-001. Human glove channels should not be assumed to transfer directly to a robot.

A tactile sensor array

Plan a tactile glove trial

Share a short task description and the signals you want to inspect.

  • Objects and hand regions of interest
  • Host environment and desired export
  • A representative recording with its signal dictionary
Discuss your application ↗